FM tuner section
Tuning range 87.5 - 108.0 MHz
Antenna FM wire antenna
Antenna terminals 75 ohms, unbalanced
Intermediate frequency 10.7 MHz
Sensitivity
Mono: 18.3 dBf, 2.2 µV/75 ohms
Stereo: 38.3 dBf, 22.5 µV/75 ohms
Useable sensitivity 11.2 dBf, 1 µV/75 ohms
S/N
Mono: 76 dB
Stereo: 70 dB
Harmonic distortion at 1 kHz
Mono: 0.3%
Stereo: 0.5%
Separation 45 dB at 1 kHz
Frequency response 30 Hz 15 kHz,
+0.5/2 dB
Selectivity 60 dB at 400 kHz
AM tuner section
Tuning range
Models of area code U, CA
With 10-kHz tuning scale: 530 1,710 kHz
6)
With 9-kHz tuning scale: 531 1,710 kHz
6)
Models of area code E2/E3
With 10-kHz tuning scale: 530 1,610 kHz
6)
With 9-kHz tuning scale: 531 1,602 kHz
6)
Models of area code CEL, CEK, SP, AU, TW, KR
With 9-kHz tuning scale: 531 1,602 kHz
Models of area code AR
With 10-kHz tuning scale: 530 1,610 kHz
Antenna Loop antenna
Intermediate frequency 450 kHz
Usable sensitivity 50 dB/m (at 1,000 kHz or
999 kHz)
S/N 54 dB (at 50 mV/m)
Harmonic distortion 0.5% (50 mV/m, 400 Hz)
Selectivity
At 9 kHz: 35 dB
At 10 kHz: 40 dB
6) You can change the AM tuning scale to 9 kHz or 10
kHz. After tuning in any AM station, turn off the
receiver. While holding down PRESET TUNING +
or TUNING +, press ?/1 . All preset stations will be
erased when you change the tuning scale. To reset
the scale to 10 kHz (or 9 kHz), repeat the procedure.
Video section
Inputs/Outputs
Video: 1 Vp-p, 75 ohms
COMPONENT VIDEO:
(Except for models of area code CEL, CEK)
Y: 1 Vp-p, 75 ohms
P
B
/C
B
/B-Y: 0.7 Vp-p,
75 ohms
P
R
/C
R
/R-Y: 0.7 Vp-p,
75 ohms
80 MHz HD Pass Through
General
Power requirements
Power consumption
Power consumption (during standby mode)
0.3 W
Dimensions (w/h/d) (Approx.)
430 × 157.5 × 312 mm
(16 7/8 × 6 2/8 × 12 2/8
inches) including
projecting parts and
controls
Mass (Approx.) 8.0 kg (17 lb 11 oz)
Supplied accessories
FM wire antenna (1)
AM loop antenna (1)
Remote commander RM-U306B (1)
R6 (size-AA) batteries (2)
Design and specifications are subject to change
without notice.
Area code Power requirements
U, CA 120 V AC, 60 Hz
CEL, CEK 230 V AC, 50/60 Hz
AU 240 V AC, 50 Hz
SP, AR, KR 220 230 V AC, 50/60 Hz
E2/E3 120/220/240 V AC, 50/60 Hz
TW 110 V AC, 50/60 Hz
Area code Power consumption
U, CEL, CEK, AU,
SP, KR, AR, E2/E3
220 W
CA 300 VA
TW 500 W
For details on the area code of the component you
are using, see page 3.